+39 0382 5169811
info@eucentre.it
Facebook
LinkedIn
YouTube
Instagram
Eucentre Foundation | Fondazione Eucentre | Dove siamo & Contatti | Progetto MATILDA | Project NAM | NAM Project | Le Persone | MATILDA Project | People
  • WHO WE ARE
    • THE FOUNDERS
    • PEOPLE
    • THE NIGEL PRIESTLEY INTERNATIONAL PRIZE
    • WORK WITH US
    • TRANSPARENT ADMINISTRATION
    • CERTIFICATIONS AND ACCREDITATIONS
    • WHERE WE ARE & CONTACTS
    • NEWSLETTER SUBSCRIPTION
  • EUCENTRE FOR
    • RESEARCH
    • INDUSTRY
    • INSTITUTIONS AND GOVERNMENTS
    • PRACTITIONERS
    • CITIZENS
    • STAKEHOLDERS AND PARTNERS
  • DEPARTMENTS
    • RISK SCENARIOS
    • EMERGENCY SUPPORT
    • EDUCATION
    • EXPERIMENTAL TECHNIQUES
    • CONSTRUCTION AND INFRASTRUCTURE
    • INDUSTRIAL PRODUCTS
  • LABORATORIES
    • SHAKELAB
    • MOBILAB
    • DATALAB
    • 6DLAB
  • PROJECTS
    • ON GOING
      • BORIS2
      • EMERGE
      • ERIES
      • GEO-INQUIRE
      • MEDIATE
      • RAISE
      • TEAMAWARE
      • U-AINSPECT
    • COMPLETED
      • BORIS
      • CRISIS
      • DRONES4SAFETY
      • ECOSTRESS
      • EPOS-IP
      • GREEN
      • ICARUS
      • INFRA-NAT
      • ISRA
      • LIQUEFACT
      • MATILDA
      • NAM
      • PEC
      • PRISMA
      • ROADMAP
      • ROADMAP2
      • SASPARM 2.0
      • SERA
      • SIMULATOR-ADS
      • STRIT
      • TURNKEY
    • MAP OF PARTNERS
  • PRODUCTS & SERVICES
    • TRAINING COURSES
    • CONSULTING
    • ALL PRODUCTS AND SERVICES
    • SOFTWARES AND
      TECHNICAL APPS
      • GIPE – Management of Building files
      • Post-EarthQuake Assessment Module
    • LABORATORY TESTS
    • PROCEDURE FOR TEMPORARY IMPORTATION OF GOODS FOR TESTING
    • CAR COLLEGE
    • EUCENTRE LIBRARY
    • BOOKSTORE
  • COMMUNICATION
    • NEWS
    • BLOG
    • VIDEO GALLERY
  • Italian

Shaking Tables: Advanced Tools for Seismic Response Analysis and Validation

07/05/2025Andrea Paoli
Tavole Vibranti Eucentre

Understanding how buildings and infrastructure react to earthquakes is fundamental to protecting lives and preventing catastrophic damage. Earthquake engineering, the field dedicated to this purpose, has made great strides in recent decades, developing increasingly sophisticated tools to study and mitigate the effects of earthquakes. Among these tools, shaking tables represent cutting-edge technology essential for analysing and confirming how structures react to seismic tremors. These sophisticated test benches make it possible to recreate the complex forces unleashed during an earthquake in the laboratory, making it possible to closely observe the behaviour of buildings, bridges, and other artifacts under extreme conditions.

The Eucentre Foundation stands out internationally as one of this field’s most advanced research centers. Equipped with state-of-the-art infrastructure, Eucentre can simulate real and artificial earthquakes with great accuracy in its laboratories. Its highlights are the mono-axial shaking table, the 6-degree-of-freedom table, and the 9-degree-of-freedom system. These are accurate benchmarks for the experimental study of the response of structures and non-structural components to the dynamic forces generated by earthquakes.

Mono-axial shaking table: the infrastructure for simulating large-scale earthquakes

Tavola Mono-Assiale/Mono-Axial Table

A high-performance mono-axial shaking table is at the heart of Eucentre’s first ShakeLab. Imagine a large 5.6 m x 7 m steel plate that can move back and forth, just as the ground would during an earthquake. This high-performance table can replicate earthquakes that have marked world history and hypothetical seismic scenarios with excellent fidelity. Its power allows the testing of entire buildings at full scale, characterised by different structural types, such as ordinary reinforced concrete structures, precast concrete structures, stone masonry structures, brick masonry, and steel and timber structures.

In addition to completing buildings on the mono-axial shaking table, it is also possible to test portions of structures rather than complex industrial elements or portions of road infrastructure.

The 6D System: analysing the dynamic interactions of non-structural elements

Sitema 6D/6D System

Since 2017, a 6-degree-of-freedom shaking table has been present at Eucentre. It represents excellence in the study of non-structural elements, i.e., those components of a building that are not part of its load-bearing framework but allow the building to function and carry out its intended activities. These elements often cause significant economic damage and, sometimes, injuries during an earthquake; for example, plants, facades, false ceilings, partitions, floating floors, air handling units, uninterruptible power supplies, sophisticated machinery, etc. The multi-axial shaking table installed in this laboratory makes it possible to test the dynamic behaviour of these elements by simultaneously subjecting them to all the stresses of an earthquake.

The name ‘6D’ refers to the six degrees of freedom with which this table is equipped. Imagine an object suspended in space: it can move back and forth, left and right, and up and down (three movements called translations), but it can also rotate on itself in three different ways (roll, pitch, and yaw, called rotations). The 6D System can reproduce all these six movements simultaneously, offering a highly realistic simulation of seismic stress. In addition, should you wish to analyse only specific components of the seismic motion, this system allows you to examine the elements of the motion that are most relevant for experimentation and not necessarily all six components.

The distinctive element of this laboratory is the combination of this six-degree-of-freedom simulator with a suspended platform with three additional degrees of freedom. This system, called 9D, allows for the effects of inter-storey displacement, i.e., the relative movement between one floor and another of a building, on the tested elements to be analysed.

The 9D System: maximum flexibility in seismic simulation

Sistema 9D/9D System

The 9D System represents the pinnacle of internationally available seismic simulation technology. By integrating the six degrees of freedom of the shaking table with three additional degrees of freedom of a suspended platform, this system can replicate in the laboratory the conditions to which a non-structural element is subjected at any plane one wishes to conceive or construct. This is particularly so because the combination of the two shaking tables makes it possible to reproduce the displacements, velocities, and accelerations of the two floors between which the object being analysed is positioned. This allows excellent flexibility in terms of experimentation because rebuilding the entire building around our non-structural element is no longer necessary. Still, it will suffice to know the vibration conditions of the floor under examination. To give an example, if we want to analyse the behaviour of an air handling unit located on the top floor of a 20-storey hospital, we will need to make an analytical model of the hospital structure subjected to an earthquake, which will tell us what the displacements, velocities, and accelerations of the floor on which the air handling unit is positioned are, and thanks to the 9D system, the movement of that particular floor on which the air handling unit to be analysed will be reproduced. This structure makes it possible to quickly consider the detailed analysis of non-structural elements on different floors without reconstructing the structure around it.

The importance of experimentation for the advancement of earthquake engineering

Eucentre’s advanced infrastructure provides crucial data for validating computational models used by engineers and developing innovative strategies for earthquake risk reduction. The ability to conduct large-scale tests makes it possible to refine technical regulations and support the design of buildings that can respond effectively to the dynamic stresses of an earthquake. For example, the results of tests conducted at Eucentre can lead to changes in building codes, making future buildings safer. In addition, testing with shaking tables can verify the behaviour of innovative construction solutions, such as using new, stronger materials or seismic isolation devices that reduce the amount of seismic energy transmitted to the building.

With its state-of-the-art research infrastructure, the Eucentre Foundation continues to play a central role in the global earthquake engineering landscape. By supporting scientific and technological progress in the field, Eucentre contributes significantly to improving the seismic safety of buildings and reducing the risk to society in the face of high-intensity seismic events. The knowledge from direct experimentation is invaluable for building a safer and more resilient future.

: advance analysis, buildings reaction, Seismic tests, shaking table, structural analysis

Copyright © 2018 | All rights reserved | Eucentre Foundation declines all responsibility for any omissions, incorrect indications or changes to the above information
European Centre for Training and Research in Earthquake Engineering | Via A. Ferrata, 1 – Pavia (Italy) | VAT Number: IT 02009180189 | Phone: +39 0382 5169811
Privacy Policy | Cookie | info@eucentre.it | protocollo@pec.eucentre.it

We use cookies on our website to give you the most relevant experience by remembering your preferences and repeat visits. By clicking “Accept”, you consent to the use of ALL the cookies.
Do not sell my personal information.
SettingsAccept
Privacy & Cookies Policy

Privacy Overview

This website uses cookies to improve your experience while you navigate through the website. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may affect your browsing experience.

Necessary
Always Enabled
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Non-necessary
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.
SAVE & ACCEPT